Back to Top

1
Hi, Guest!

UPS ICA SIN5100C

Update Terakhir
:
09 / 04 / 2021
Min. Pembelian
:
1 Unit

Harga

Rp. 1.000
PT. Trikomindo Kharis Utama ( Trikom Kharisma) adalah perusahaan yang bergerak di bidang Teknologi Informasi / Information Technology ( IT) dan berperan sebagai System Integrator, Network Solution, Distributor, Master Dealer, Dealer, Reseller dan Authorized.

Detail UPS ICA SIN5100C

Kami merupakan authorized dealer resmi yang menjual Produk UPS ICA.
Jual UPS ICA SIN5100C 8KVA.
Kami juga menjual UPS ICA SIN Series Lainnya.

ICA TP SERIES
- SIN 1100C 1600VA
- SIN 1500C 2500VA
- SIN 2100C 3100VA
- SIN 3100C 5KVA
- SIN 5100C 8KVA
- SIN 5100C3 8KVA
- SIN 7501C1 10KVA
- SIN 7501C3 10KVA
- SIN 1002C1 12.5KVA
- SIN 1002C3 12.5KVA
- SIN 1502C1 18KVA
- SIN 1502C3 18KVA
- SIN 2002C1 25KVA
- SIN 2002C3 25KVA

Berikut ini spesifikasi UPS ICA SIN series :

Description : UPS SIN2100C
Capacity : 3100 VA / 2015 W
AC Voltage : 185 - 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 120 V
DC INT Battery : 10 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 136 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 630 x 265 x 610 mm
Weight : 85 Kg


Description : UPS SIN3100C
Capacity : 5000 VA / 3250 W
AC Voltage : 185 - 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 630 x 265 x 690 mm
Weight : 110 Kg


Description : UPS SIN5100C
Capacity : 8000 VA / 5200 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 14 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 648 x 360 x 846 mm
Weight : 240 Kg

Description : UPS SIN5100C3
Capacity : 8000 VA / 5200 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 14 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 648 x 360 x 846 mm
Weight : 240 Kg


Description : UPS SIN7501C1
Capacity : 10000 VA / 6500 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 17 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 307 Kg


Description : UPS SIN7501C3
Capacity : 10000 VA / 6500 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 17 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 307 Kg

Description : UPS SIN1002C1
Capacity : 12500 VA / 8125 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 24 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 364 Kg

Description : UPS SIN1002C3
Capacity : 12500 VA / 8125 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 24 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 364 Kg

Description : UPS SIN1502C1
Capacity : 18000 VA / 11700 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 24 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 383 Kg

Description : UPS SIN1502C3
Capacity : 18000 VA / 11700 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 24 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 383 Kg

Description : UPS SIN2002C1
Capacity : 25000 VA / 16250 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 38 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 870 x 595 x 1315 mm
Weight : 490 Kg

Description : UPS SIN2002C3
Capacity : 25000 VA / 16250 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 38 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 870 x 595 x 1315 mm