Kami merupakan authorized dealer resmi yang menjual Produk UPS ICA.
Jual UPS ICA SIN5100C 8KVA.
Kami juga menjual UPS ICA SIN Series Lainnya.
Berikut ini spesifikasi UPS ICA SIN series :
Description : UPS SIN2100C
Capacity : 3100 VA / 2015 W
AC Voltage : 185 - 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 120 V
DC INT Battery : 10 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 136 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 630 x 265 x 610 mm
Weight : 85 Kg
Description : UPS SIN3100C
Capacity : 5000 VA / 3250 W
AC Voltage : 185 - 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 630 x 265 x 690 mm
Weight : 110 Kg
Description : UPS SIN5100C
Capacity : 8000 VA / 5200 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 14 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 648 x 360 x 846 mm
Weight : 240 Kg
Description : UPS SIN5100C3
Capacity : 8000 VA / 5200 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 14 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 648 x 360 x 846 mm
Weight : 240 Kg
Description : UPS SIN7501C1
Capacity : 10000 VA / 6500 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 17 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 307 Kg
Description : UPS SIN7501C3
Capacity : 10000 VA / 6500 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 17 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 307 Kg
Description : UPS SIN1002C1
Capacity : 12500 VA / 8125 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 24 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 364 Kg
Description : UPS SIN1002C3
Capacity : 12500 VA / 8125 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 24 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 364 Kg
Description : UPS SIN1502C1
Capacity : 18000 VA / 11700 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 24 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 383 Kg
Description : UPS SIN1502C3
Capacity : 18000 VA / 11700 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 24 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 765 x 595 x 1120 mm
Weight : 383 Kg
Description : UPS SIN2002C1
Capacity : 25000 VA / 16250 W
AC Voltage : SINGLE PHASE, 3 WIRE 220 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 38 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 870 x 595 x 1315 mm
Weight : 490 Kg
Description : UPS SIN2002C3
Capacity : 25000 VA / 16250 W
AC Voltage : THREE PHASE, 4 WIRE 380 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 38 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Waveform : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
Buzer UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 - 40 °C
Dimension (DxWxH) : 870 x 595 x 1315 mm
Weight : 490 Kg
(Harga yang tertera di kolom harga, bukan harga sebenarnya)
Hubungi kami segera untuk mendapatkan informasi mengenai tipe, harga dan stok terbaru.
PT. Trkomindo Kharis Utama
Tags:
distributor ups ica indonesia jakarta mangga dua master dealer authorized dealer resmi ups ica indonesia jual ups ica harga ups ica murah promo ups ica stabilizer ica distributor ica indonesia ica ups line interactive ica ups offline ica ups online ica ups sine wave